Filter Cleaning Process

图片
The whole cleaning process of the filter press, we all know, after the filter press operation, there will be a little residue of filter residue. In order not to affect the further filtration operation, we need to clean the filter press in time. As a  Vehicle Mounted Filter Press Supplier , we have summarized the entire process of filter press cleaning, which is summarized as follows: The first thing to note is that before cleaning, we need to understand the properties of the filter cloth filter, so as to choose the corresponding cleaning method. 1. Select the weak base water and soak the filter cloth for 10~24 hours. 2. Then repeat the sputum on the filter cloth, wash it with clean water, then dry it to 90% dry and then operate again. Secondly, we can use the manual method when cleaning the  Plate and Frame Jack Compacting Filter Press . 1. Remove the filter from the plate frame and soak it in water. 2. Repeatedly rubbing with your hands, plus detergent. 3. You ...

What Are The Safety Requirements For Filter Press Operation? 2

图片
As a  Filter Press Accessories Supplier , we continue to share with you the safe operation requirements of the filter press. 5. When the feeding of the equipment is not finished, it is forbidden to loosen the filter plate according to the stroke switch, otherwise it will cause material leakage and even cause personal injury. 6. When the equipment is being repaired, the total power switch of the filter press should be turned off. 7. When rinsing the filter cloth, water is not allowed to splash on the electrical components. 8. It is forbidden to operate the filter press when the filter plate is missing, so as to avoid accidents caused by insufficient stroke of the cylinder. 9. If the electric contact pressure gauge and overflow valve of  Chamber Filter Press  are damaged, they should be replaced in time to prevent the hydraulic cylinder from being in a high pressure state for a long time, causing personnel damage caused by bursting.

What Causes The Filter Press To Stop Working?

图片
In some cases, the filter press may stop working during the working process, which is very bad for the machine, which causes the filter press to stop working. As a  Filter Press Accessories Supplier  Let us analyze it together. An error in the filter press control system can cause the filter press equipment to stop working. We all know that when the filter press equipment is working, it needs a control system to control the hydraulic system and control the range of its expansion and contraction, so as to control the power generated by the hydraulic system to the filter plate, and the power received by the filter plate can be transmitted to the filter. On the liquid, and the filtrate is directly exposed by the pressure to penetrate the filter cloth, so the control system of the filter press equipment directly affects the filtration of the filtrate. When there is an error in the control system, or the control of the hydraulic system can not be issued, or the control syste...

13 Notes On Membrane Filter Press 2

图片
As a  Hydraulic Filter Press Factory , we continue to share the precautions for diaphragm filter presses. 8. Once the equipment starts working, the equipment cannot be adjusted. If the pressure gauge is damaged or the pressure gauge is not installed, it must not be turned on; 9. When the oil pipe is replaced for the first time, the operator should stay away from the high pressure oil pipe; 10. The equipment can not be overloaded for a long time, otherwise it may burn out the motor or damage the parts; 11. Clean up the entry and exit channels in time, and prevent the blockage of the import and export channels; 12. When removing slag, clean the filter cloth and the plate frame; 13. The filter plate and filter frame should not be exposed to oil, acid and alkali, etc. Keep away from heat and sunlight. Our company also offers the  Round High Pressure Filter Press . Welcome to contact us.

13 Notes On Membrane Filter Press 1

图片
As a  Vehicle Mounted Filter Press Supplier , we have 13 recommendations for the use of Membrane Filter Press. 1. The staff must be familiar with the manual when operating the diaphragm filter press, and must follow the instructions and do not operate indiscriminately. 2. The quality of the filter cloth must be good, no wrinkles, damage, etc.; 3. Always check whether the installation of equipment parts is safe, tight, and oil leakage; 4. Hydraulic oil quality and oil level must be operated according to requirements; 5. The oil temperature should not be too high, preferably less than 60 ° C; do not let water and dust enter the mailbox; 6. Clean the oil filter frequently; 7. The newly purchased  Automatic Plate Pulling Membrane Filter Press  should clean the fuel tank, oil cylinder, oil circuit, etc. after one month, and then replace and clean it once every six months;

How To Solve The Overheating Problem Of The Filter Press?

图片
If the filter press is overheated, it will not only have a great impact on the operation of the staff, but also will have a certain influence on the filtrate during the operation, which will cause a change in the filtrate, and then affect the effect of separation, so in operation The process of overheating of the filter press should be noted. As a  Filter Equipment Company , we have the following recommendations. 1. If the diaphragm filter press bearing is damaged, it should be replaced in time. When installing new bearings, it requires very strict standards. Be careful and careful. 2. Prevent the bearing from being subjected to severe impact and prevent the occurrence of scratches, indentations and cracks. 3. During the application of the  Membrane Filter Press , it is necessary to pay attention to the anti-rust treatment of the bearings, and do not let the water get too much. Clean the periphery of the housing, apply lubricant, and maintain.

Reasons For Overheating Membrane Filter Press

图片
As a  Filter Accessories And Equipment Factory , let's talk about the reasons for the overheating of the Membrane Filter Press.There are two reasons why the Membrane Filter Press is overheated: one is the hydraulic system and the other is the Membrane Filter Press filter plate. The hydraulic system of the filter press is closely related to the temperature. It can control the hydraulic system through the heat release device of the device, so that the filter press can operate normally, and the demand is particularly important that the temperature of the hydraulic station should not be too high, because This will affect the hydraulic system and then cause the system to not function properly. The Membrane Filter Press filter plate is made of polypropylene. It can be used to avoid overheating, slow down the temperature, reduce the differentiation and oxidation of the  Membrane Filter Press  filter plate, and the application cycle of the filter plate.  Reduce the damage o...

How Is The Dewatering Filter Press Dehydrated?

图片
As a  Filter Press Accessories Supplier , let's talk about how Filter Press For Wastewater Treatment helps sludge dewatering.The dewatering filter press sewage includes the remaining activated sludge discharged from the secondary settling tank of the domestic sewage plant; the physicochemical sludge discharged from the sedimentation tank or the concentration tank of the tap water plant; the physicochemical and biochemical mixed sludge discharged from the concentrated tank produced by the sewage industrial wastewater treatment Such as paper mills, printing and dyeing plants, water washing cloth factories, meat joint factories and brewing plants; physicochemical and biochemical mixed sludge discharged from the concentration tank produced by chemical industry wastewater treatment, such as petrochemical plants, organic chemical plants, etc.; Filter Press For Wastewater Treatment The process of concentrating or digesting a fluid mixture to reduce, remove moisture, and convert it in...

Chamber Filter Press Base Installation Can Not Be Ignored

图片
As a  Filter Accessories And Equipment Factory , let's talk about the installation of the Chamber Filter Press. The first point that needs attention to the device requirements of the Chamber Filter Press base is that the filter press must be placed on a very stable concrete floor, and the space in which it is located is in great demand. The second point that needs attention to the device requirements of the Chamber Filter Press base is that in addition to the above conditions, it is necessary to use the screws to perform a fixed behavior on the local thrust plate legs of the feed. It is necessary to check whether it is tightened. In addition, the staff is sure to ensure that the beam and the thrust plate are in a straight condition. Just do the above thing when we installed the device,  Chamber Filter Press  can be installed very well. Of course, the environment should also pay attention. It must be dry and clean. The above is the precautions when installing the ...

How To Reduce The Loss Of The Automatic Pressure Maintaining Filter?

图片
Some customers feel that the pressure loss of the filter press is getting bigger and bigger after using the Automatic Pressure Maintaining Filter for a period of time. A large part of the situation is caused by the lack of pressure of the filter press. On the one hand, the machine itself is aging or malfunctioning. When the machine is running, it may overheat, which is relatively large for the filter plate and filter cloth. When the loss of the filter press is increased, find the cause of the problem, solve the problem as soon as possible, and do not let the equipment always be in a fault condition. As a  Filter Accessories And Equipment Factory , we have the following recommendations. 1. When the sludge is too thick or dry, it will cause blockage of the feed port. At this time, there is no medium between the filter plates, only the pressure of the hydraulic system itself is left. damage. A nylon cleaning blade should be used to remove the mud from the feed port. 2. Insufficie...